China WNS Gas Fired Boiler fabryk en leveransiers | Taishan Group

WNS Gas Fired Boiler

Koarte beskriuwing:

WNS Oil Fired Boiler Product Description WNS series gas ûntslein steam boiler is trije-pass fol wiet werom struktuer, it oannimmen grutte oun en tichte reek piip te fergrutsjen de waarmte opname fan 'e oun en effektyf besparje enerzjy en ferminderjen konsumpsje. De Threaded piip en corrugated furnace sterk fergrutsje de waarmte oerdracht effekt en sterk besparje brandstof konsumpsje. De wichtichste bouwurk befettet: ketel shell, Famke Fan Myn Dreamen oun, omkearing keamer, draad reek buis, ensfh De burner merk kin b ...


  • Min.Order Quantity: 1 set
  • Supply Mooglikheid: 50 sets per moanne
  • produkt Detail

    produkt Tags

    WNS Oil Fired Boiler

    produkt Omskriuwing

    WNS series gas fired steam boiler is three-pass full wet back structure, adopting large furnace and thick smoke pipe to increase the heat absorption of the furnace and effectively save energy and reduce consumption. The threaded pipe and corrugated furnace greatly enhance the heat transfer effect and greatly save fuel consumption. The main structure includes: boiler shell, ripple furnace, reversal chamber, thread smoke tube, etc. The burner brand can be chosen according to user' s requirement.

    WNS rige gas ûntslein steam boiler is ûntwurpen en optimalisearre te produsearje lege druk steam of hjit wetter mei rated ferdamping kapasiteit fan 1 oant 20 ton / oere en rated druk fan 0,7 oant 1.6MPa. It ûntwerp waarmte effisjinsje is maksimaal 95%.

    Features:

    1. Der is mear heating oerflak te spare te fersekerje rinnen fan folle lading en overcharge.
    2. De boilers wurde ôfstimd mei ymportearre burner fan de Europeeske merk. Evenredige kontrôle, proseduere ûntstekking, automatische waait en flameout beskermjende apparaat. De baarnende effisjinsje is mear as 99,5%.
    3. De furnace foarm is fit foar de foarm fan flam, it foarkommen fan de flamme waskjen út de ferwaarming oerflak.
    4. De temperatuer fan de efterste flue keamer is leech, sadat de operators fiele noflik en feilich.
    5. Boiler oannimt licht kwaliteit termyske isolaasje materiaal: aluminium silicate fiber, goede waarmte behâld, minder waarmte ferlern, hege ferwaarming efficiency.
    6. De automatyske kontrôle fak oannimt fol automatyske bestjoeringssysteem te mar troch auto-igniting en auto-stroomûnderbrekking. En soks hat ek hânmjittich switch.
    7. De automatyske kontrôle beskerming proseduere hat folle funksjes, lykas automatyske waait, brânstof gaslek alarm, feilich bestjoeringssysteem interlock beskerming, flameout beskerming, brânstof gas druk beskerming.
    8. Boiler set de eksploazje-bewiis poarte te hâlden feilich.
    9. Boiler wurdt ferpakt ferlitten fan it fabryk, ynstallearre en oanpast yn it lokaal.

    Oanfraach:

    WNS rige gas ûntslein steam boiler wurdt in soad brûkt yn de gemyske yndustry, papieren making yndustry, tekstylyndustry, iten yndustry, pharmaceuticals yndustry, ferwaarming yndustry, bou yndustry.

     

    Technyske Gegevens fan WNS Gas Fired Hot Water Boiler
     Model Rated Thermal Power (MW) Rated Output Luftdruck (MPa) Rated Output Temperatur (° C) Rated Input Temperatur (° C) Heating Area
    (m²)
    Furnace folume (m³) Flue Gas Temperatur (° C) Fuel Consumption (m³ / h) Max Sylskippen (Ton) Max Transport Dimension (mm)
    WNS0.7-0.7 / 95/70-Q 0.7 0.7 95 70 18.5 0.7 161 77 4.5 3130x1600x2040
    WNS1.4-0.7 / 95/70-Q 1.4 0.7 95 70 42,7 1.4 155 156 7.2 4100x2100x2434
    WNS1.4-1.0 / 95/70-Q 1.4 1 95 70 42,7 1.4 155 154 7.2 4100x2100x2434
    WNS2.1-1.0 / 95/70-Q 2.1 1 95 70 63.2 2.5 140 234 8.9 4765x2166x2580
    WNS2.8-0.7 / 95/70-Q 2.8 0.7 95 70 84.3 2.5 140 311 9.1 4765x2166x2580
    WNS2.8-1.0 / 95/70-Q 2.8 1 95 70 84.3 2.5 140 311 9.1 4765x2166x2580
    WNS4.2-0.7 / 95/70-Q 4.2 0.7 95 70 132.1 4.7 162 463 9.1 5570x2400x2714
    WNS4.2-1.0 / 95/70-Q 4.2 1 95 70 132.1 4.7 162 467 12.9 5570x2400x2714
    WNS4.2-1.0 / 115/70-Q 4.2 1 115 70 132.1 4.7 162 467 12.9 5570x2400x2714
    WNS5.6-1.0 / 95/70-Q 5.6 1 95 70 153.3 5.4 163 624 18.6 6490x2910x3230
    WNS5.6-1.0 / 115/70-Q 5.6 1 115 70 153.3 5.4 163 617 18.6 6000x2645x3053
    WNS7-1.0 / 95/70-Q 7 1 95 70 224.6 6.2 163 770 21.3 6620x2700x3374
    WNS7-1.0 / 115/70-Q 7 1 115 70 224.6 6.2 163 770 21.3 6334x2814x3235
    WNS10.5-1.0 / 95/70-Q 10.5 1 95 70 281 11.8 155 1159 30.3 7644x3236x3598
    WNS10.5-1.25 / 115/70-Q 10.5 1.25 115 70 281 11.8 155 1155 30.3 7644x3236x3598
    WNS14-1.0 / 95/70-Q 14 1 95 70 390,8 16.8 160 1531 31.4 7850x3500x3500
    WNS14-1.25 / 115/70-Q 14 1.25 115 70 390,8 16.8 160 1534 31.4 7850x3500x3500
    WNS14-1.6 / 130/70-Q 14 1.6 130 70 390,8 16.8 160 1550 31.4 8139x3616x3640
    Opmerke 1. Design effisjinsje is 92 ~ 95%. 2. LHV is basearre op 35588KJ / Nm3.

     

    Technyske Gegevens fan WNS Gas Fired Steam Boiler
     Model Rated ferdamping Kapasiteit (t / h) Rated Steam Luftdruck (MPa) Rated Steam Temperatur (° C) Feed Water Temperatur (° C) Heating Area
    (m²)
    Furnace folume (m³) Flue Gas Temperatur (° C) Fuel Consumption (m³ / h) Max Sylskippen (t) Max Transport Dimension (mm)
    WNS1-0.7-Q 1 0.7 170 20 21,52 0,74 157 81 4.9 3540x1926x2212
    WNS1-1.0-Q 1 1 184 20 21,52 0,74 165 82 4.9 3540x1926x2212
    WNS2-0.7-Q 2 0.7 170 20 49,72 1.47 158 162 8.4 4220x2215x2540
    WNS2-1.0-Q 2 1 184 20 49,72 1.47 138 162 8.4 4220x2215x2540
    WNS2-1.25-Q 2 1.25 193 20 49,72 1.47 144 162 8.4 4220x2215x2540
    WNS3-1.25-Q 3 1.25 193 20 71,86 2.16 163 246 10.3 4807x2308x2634
    WNS4-1.0-Q 4 1 184 20 99,62 2.85 158 323 12.3 5610 × 2410 × 2720
    WNS4-1.25-Q 4 1.25 193 20 99,62 2.85 160 323 12.3 5610 × 2410 × 2720
    WNS4-1.6-Q 4 1.6 204 20 99,62 2.85 167 324 12.3 5610 × 2410 × 2720
    WNS6-1.0-Q 6 1 184 105 149,22 3,89 152 418 15.1 5962 × 2711 × 3034
    WNS6-1.25-Q 6 1.25 193 105 149,22 3,89 167 419 15.1 5962 × 2711 × 3034
    WNS6-1.6-Q 6 1.6 204 105 149,22 3,89 167 420 15.1 5962 × 2711 × 3034
    WNS8-1.0-Q 8 1 184 105 186,33 5.1 155 556 20.3 6500x2930x3200
    WNS8-1.25-Q 8 1.25 193 105 186,33 5.1 165 560 20.3 6500x2930x3200
    WNS8-1.6-Q 8 1.6 204 105 186,33 5.1 169 562 20.3 6500x2930x3200
    WNS10-1.25-Q 10 1.25 193 105 218,63 5.8 157 694 21.9 6420x2930x3360
    WNS10-1.6-Q 10 1.6 204 105 218,63 5.8 168 712 21.9 6420x2930x3360
    WNS15-1.25-Q 15 1.25 193 105 285,9 11.6 170 1050 35 7500x3250x3700
    WNS15-1.6-Q 15 1.6 204 105 285,9 11.6 166 1057 35 7500x3250x3700
    WNS20-1.25-Q 20 1.25 193 105 440 16 164 1391 43.2 8160x3680x3750
    WNS20-1.6-Q 20 1.6 204 105 440 16 165 1401 43.2 8160x3680x3750
    Opmerke 1. Design effisjinsje is 92 ~ 95%. 2. LHV is basearre op 35588KJ / Nm3.

     

    150507 总 图 -Model


  • Foarige:
  • Folgjende:

  • Skriuw dyn berjocht hjir en stjoer it nei ús

    Relatearre produkten

    • WNS Oil Fired Boiler

      WNS Oil Fired Boiler

      WNS Oil Fired Boiler Product Description WNS series oalje boiler oannimt Famke Fan Myn Dreamen oun, screw thread reek buis, hege doelmjittigens, enerzjy besparje, horizontal trije-pass, wiet werom struktuer, folslein automatyske kontrôle, ridlike struktuer, maklik en feilich wurking. Nei de oalje wurdt atomized troch de lange baan skood, de fakkel is ynfolle yn de corrugated oune en stjoert strieljende waarmte troch de ûne muorre, dat is de earste pas. De hege temperatuer flue gas oanmakke út de ferbaarning verzamelt yn 'e ...

    • SZS Oil Fired Boiler

      SZS Oil Fired Boiler

      SZS Oil Fired Boiler Product Description SZS series oalje ûntslein steam boiler is dûbele tromme, longitudinale yndieling, D type struktuer. De rjochter kant is de oun, en de lofter kant is it convection buis bondel. De superheater is ynrjochte yn de convection buis bondel, en is fêst op it lichem basis fia de beweechbere stipe fan de legere tromme. De ûne wurdt omjûn troch in membraan wetter muorre. De membraan wetter muorre oan de linker kant fan 'e ûne skiedt de ûne en de convection tube b ...

    • SZS gas ûntsleine ketel

      SZS gas ûntsleine ketel

      SZS Oil Fired Boiler Product Description SZS series gas steam boiler is with D-type arrangement, natural recycling, double-drum water tube boiler. Longitudinal drum, full membrane wall structure, slightly positive pressure combustion. Furnace is wrapped by membrane wall, smoke enters the convection bank which is between the upper and lower drum from furnace exit, and then enters the tail heating surface -- steel spiral fin economizer. SZS series gas steam boiler is designed and optimized to p...