WNS caldera de gas
WNS caldera de gasoil
Descripción del producto
WNS series gas fired steam boiler is three-pass full wet back structure, adopting large furnace and thick smoke pipe to increase the heat absorption of the furnace and effectively save energy and reduce consumption. The threaded pipe and corrugated furnace greatly enhance the heat transfer effect and greatly save fuel consumption. The main structure includes: boiler shell, ripple furnace, reversal chamber, thread smoke tube, etc. The burner brand can be chosen according to user' s requirement.
gas de la serie WNS caldera de vapor está diseñada y optimizada para producir vapor de baja presión o agua caliente con capacidad de evaporación Calificación de 1 a 20 ton / hora y la presión nominal de 0,7 1.6mpa. La eficiencia térmica de diseño es de hasta el 95%.
caracteristicas:
1. Hay más superficie de calentamiento de sobra para asegurar funcionamiento de plena carga y sobrecarga.
2. Las calderas están emparejados con quemador importado de marca europea. El control proporcional, el encendido procedimiento, soplado automático y dispositivo de protección del apagado. La eficiencia de combustión es superior al 99,5%.
3. La forma del horno es apto para la forma de la llama, evitando el lavado de la llama fuera de la superficie de calefacción.
4. La temperatura de la cámara de combustión trasera es baja, de modo que los operadores se sientan cómodos y seguros.
5. Caldera adopta calidad material ligero de aislamiento térmico: fibra de silicato de aluminio, buena preservación del calor, menos calor perdido, alta eficiencia de calefacción.
6. La caja de control automático adopta funcionamiento completamente automático para actualizar auto-ignición y de auto-interrupción. Y también dispone de un interruptor manual.
7. El procedimiento de protección automática de control tiene funciones completas, tales como soplado automático, alarma de fuga de gas combustible, la protección de bloqueo de funcionamiento seguro, la protección del apagado, la protección de la presión del gas combustible.
8. Caldera establece la puerta a prueba de explosiones para mantenerse a salvo.
9. Caldera se envasa salir de la fábrica, instalado y ajustado en el local.
Solicitud:
gas de la serie WNS caldera de vapor se utiliza ampliamente en la industria química, papel industria de la fabricación, industria textil, industria alimentaria, industria farmacéutica, industria de la calefacción, industria de la construcción.
Datos técnicos de WNS caldera de gas Agua Caliente | ||||||||||
Modelo | Potencia nominal térmica (MW) | Calificación presión de salida (MPa) | Temperatura nominal de salida (° C) | Calificación Temperatura de entrada (° C) | Zona de calentamiento (m²) |
volumen del horno (m³) | Flue Gas Temperatura (° C) | Consumo de Combustible (m³ / h) | Peso máximo de Transporte (Ton) | Dimensión Transporte Max (mm) |
WNS0.7-0.7 / 95/70-Q | 0.7 | 0.7 | 95 | 70 | 18.5 | 0.7 | 161 | 77 | 4.5 | 3130x1600x2040 |
WNS1.4-0.7 / 95/70-Q | 1.4 | 0.7 | 95 | 70 | 42.7 | 1.4 | 155 | 156 | 7.2 | 4100x2100x2434 |
WNS1.4-1.0 / 95/70-Q | 1.4 | 1 | 95 | 70 | 42.7 | 1.4 | 155 | 154 | 7.2 | 4100x2100x2434 |
WNS2.1-1.0 / 95/70-Q | 2.1 | 1 | 95 | 70 | 63,2 | 2.5 | 140 | 234 | 8.9 | 4765x2166x2580 |
WNS2.8-0.7 / 95/70-Q | 2.8 | 0.7 | 95 | 70 | 84.3 | 2.5 | 140 | 311 | 9.1 | 4765x2166x2580 |
WNS2.8-1.0 / 95/70-Q | 2.8 | 1 | 95 | 70 | 84.3 | 2.5 | 140 | 311 | 9.1 | 4765x2166x2580 |
WNS4.2-0.7 / 95/70-Q | 4.2 | 0.7 | 95 | 70 | 132,1 | 4.7 | 162 | 463 | 9.1 | 5570x2400x2714 |
WNS4.2-1.0 / 95/70-Q | 4.2 | 1 | 95 | 70 | 132,1 | 4.7 | 162 | 467 | 12.9 | 5570x2400x2714 |
WNS4.2-1.0 / 115/70-Q | 4.2 | 1 | 115 | 70 | 132,1 | 4.7 | 162 | 467 | 12.9 | 5570x2400x2714 |
WNS5.6-1.0 / 95/70-Q | 5.6 | 1 | 95 | 70 | 153,3 | 5.4 | 163 | 624 | 18.6 | 6490x2910x3230 |
WNS5.6-1.0 / 115/70-Q | 5.6 | 1 | 115 | 70 | 153,3 | 5.4 | 163 | 617 | 18.6 | 6000x2645x3053 |
WNS7-1.0 / 95/70-Q | 7 | 1 | 95 | 70 | 224.6 | 6.2 | 163 | 770 | 21.3 | 6620x2700x3374 |
WNS7-1.0 / 115/70-Q | 7 | 1 | 115 | 70 | 224.6 | 6.2 | 163 | 770 | 21.3 | 6334x2814x3235 |
WNS10.5-1.0 / 95/70-Q | 10.5 | 1 | 95 | 70 | 281 | 11,8 | 155 | 1159 | 30.3 | 7644x3236x3598 |
WNS10.5-1.25 / 115/70-Q | 10.5 | 1.25 | 115 | 70 | 281 | 11,8 | 155 | 1155 | 30.3 | 7644x3236x3598 |
WNS14-1.0 / 95/70-Q | 14 | 1 | 95 | 70 | 390.8 | 16.8 | 160 | 1531 | 31.4 | 7850x3500x3500 |
WNS14-1.25 / 115/70-Q | 14 | 1.25 | 115 | 70 | 390.8 | 16.8 | 160 | 1534 | 31.4 | 7850x3500x3500 |
WNS14-1.6 / 130/70-Q | 14 | 1.6 | 130 | 70 | 390.8 | 16.8 | 160 | 1550 | 31.4 | 8139x3616x3640 |
Observación | 1. Diseño de eficiencia es del 92 ~ 95%. 2. LHV se basa en 35588KJ / Nm3. |
Datos técnicos de WNS caldera de gas de vapor | ||||||||||
Modelo | Calificación de evaporación Capacidad (t / h) | Calificación de presión de vapor (MPa) | Calificación temperatura del vapor (° C) | Temperatura del agua de alimentación (° C) | Zona de calentamiento (m²) |
volumen del horno (m³) | Flue Gas Temperatura (° C) | Consumo de Combustible (m³ / h) | Max Peso de transporte (T) | Dimensión Transporte Max (mm) |
WNS1-0.7-Q | 1 | 0.7 | 170 | 20 | 21.52 | 0,74 | 157 | 81 | 4.9 | 3540x1926x2212 |
WNS1-1.0-Q | 1 | 1 | 184 | 20 | 21.52 | 0,74 | 165 | 82 | 4.9 | 3540x1926x2212 |
WNS2-0.7-Q | 2 | 0.7 | 170 | 20 | 49.72 | 1.47 | 158 | 162 | 8.4 | 4220x2215x2540 |
WNS2-1.0-Q | 2 | 1 | 184 | 20 | 49.72 | 1.47 | 138 | 162 | 8.4 | 4220x2215x2540 |
WNS2-1.25-Q | 2 | 1.25 | 193 | 20 | 49.72 | 1.47 | 144 | 162 | 8.4 | 4220x2215x2540 |
WNS3-1.25-Q | 3 | 1.25 | 193 | 20 | 71.86 | 2.16 | 163 | 246 | 10.3 | 4807x2308x2634 |
WNS4-1.0-Q | 4 | 1 | 184 | 20 | 99.62 | 2.85 | 158 | 323 | 12.3 | 5610 × 2410 × 2720 |
WNS4-1.25-Q | 4 | 1.25 | 193 | 20 | 99.62 | 2.85 | 160 | 323 | 12.3 | 5610 × 2410 × 2720 |
WNS4-1.6-Q | 4 | 1.6 | 204 | 20 | 99.62 | 2.85 | 167 | 324 | 12.3 | 5610 × 2410 × 2720 |
WNS6-1.0-Q | 6 | 1 | 184 | 105 | 149.22 | 3.89 | 152 | 418 | 15.1 | 5962 × 2711 × 3034 |
WNS6-1.25-Q | 6 | 1.25 | 193 | 105 | 149.22 | 3.89 | 167 | 419 | 15.1 | 5962 × 2711 × 3034 |
WNS6-1.6-Q | 6 | 1.6 | 204 | 105 | 149.22 | 3.89 | 167 | 420 | 15.1 | 5962 × 2711 × 3034 |
WNS8-1.0-Q | 8 | 1 | 184 | 105 | 186.33 | 5.1 | 155 | 556 | 20.3 | 6500x2930x3200 |
WNS8-1.25-Q | 8 | 1.25 | 193 | 105 | 186.33 | 5.1 | 165 | 560 | 20.3 | 6500x2930x3200 |
WNS8-1.6-Q | 8 | 1.6 | 204 | 105 | 186.33 | 5.1 | 169 | 562 | 20.3 | 6500x2930x3200 |
WNS10-1.25-Q | 10 | 1.25 | 193 | 105 | 218.63 | 5.8 | 157 | 694 | 21.9 | 6420x2930x3360 |
WNS10-1.6-Q | 10 | 1.6 | 204 | 105 | 218.63 | 5.8 | 168 | 712 | 21.9 | 6420x2930x3360 |
WNS15-1.25-Q | 15 | 1.25 | 193 | 105 | 285,9 | 11.6 | 170 | 1050 | 35 | 7500x3250x3700 |
WNS15-1.6-Q | 15 | 1.6 | 204 | 105 | 285,9 | 11.6 | 166 | 1057 | 35 | 7500x3250x3700 |
WNS20-1.25-Q | 20 | 1.25 | 193 | 105 | 440 | 16 | 164 | 1391 | 43.2 | 8160x3680x3750 |
WNS20-1.6-Q | 20 | 1.6 | 204 | 105 | 440 | 16 | 165 | 1401 | 43.2 | 8160x3680x3750 |
Observación | 1. Diseño de eficiencia es del 92 ~ 95%. 2. LHV se basa en 35588KJ / Nm3. |